Myson 7-4 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Aquecedores elétricos Myson 7-4. Parts Catalog - New England Outdoor Furnaces Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 28
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
TABLE OF CONTENTS
Water-to-Air Heat Exchanger Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Pumps and Pump Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
PEX Pipe, Fittings and Related . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
ThermoPEX, Central Therm, Manifolds and Water-to-Water Exchangers . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Water-to-Water Exchangers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Connections, Solder and Flux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Valves, Manifolds, Strainers, Connections, Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Thermostats, Transformers, Aquastats. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Baseboards, Copper Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Push- t Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Maintenance, Replacement and Optional Products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Maintenance, Replacement and Optional Products - Classic and Pallet Burner . . . . . . . . . . . . . . . . . . . . .15
Maintenance, Replacement and Options Products - E-Classic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Chimney Components - Classic, E-Classic and Pallet Burner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-18
Maintenance, Replacement and Optional Products - Maxim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-20
Chimney Components - Maxim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-22
NUMERICAL PARTS LIST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-24
DEFINITIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
SAMPLE PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
NOTE
All installations must be performed by a quali ed installer and in accordance with any and
all federal, state/provincial and local codes and regulations. When performing work on an
appliance observe all precautions in the literature, tags and labels attached to the appliance
and other safety precautions that may apply. When working with electricity and electrical
components, failure to follow precautions could result in property damage, personal injury
or death.
i
Vista de página 0
1 2 3 4 5 6 ... 27 28

Resumo do Conteúdo

Página 1

TABLE OF CONTENTSWater-to-Air Heat Exchanger Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 2 - ALPHABETICAL INDEX

9October 2011CONNECTIONS, SOLDER AND FLUXSolder & Soldering FluxLow melting-point solder for easier soldering. Soldering fl ux includes brush. Use

Página 3 - 16"

10October 2011VALVES, MANIFOLDS, STRAINERS, CONNECTIONS, ADAPTERS3/4" Thermostatic ValveThermostatic Valve prevents the water temperature from dr

Página 4 - 17"

11October 2011THERMOSTATS, TRANSFORMERS, AQUASTATSLine Voltage ThermostatOFF• 40 • 50 • 60 • 70 • 80 •FHon

Página 5 - 20-3/16"

12October 2011BASEBOARDS, COPPER CONNECTIONSBaseboard JoinerUsed to cover joints in continuous lengths of baseboard.p/n Description230 Baseboard Join

Página 6 - PUMPS AND PUMP ACCESSORIES

13October 2011PUSH-FIT FITTINGSPush-fi t FittingsPush-fi t Fittings are designed to simplify pipe installation. The fi ttings allow the user to connect p

Página 7

14October 2011MAINTENANCE, REPLACEMENT AND OPTIONAL PRODUCTSWater Softener CartridgeFor single use in fi lling water jacket, Water Softener Cartridge h

Página 8 - ThermoPEX

15October 2011MAINTENANCE, REPLACEMENT AND OPTIONAL PRODUCTS - CLASSIC AND PALLET BURNERHoeUsed as a fi rebox maintenance tool, hoe comes with metal ha

Página 9 - WATER-TO-WATER EXCHANGERS

16October 2011MAINTENANCE, REPLACEMENT AND OPTIONAL PRODUCTS - E-CLASSICGas Burner KitsTransformerGasPressureDamperOpenAirFlowGasValveOptional LP gas

Página 10 - CONNECTIONS, SOLDER AND FLUX

17October 2011CHIMNEY COMPONENTS - CLASSIC, E-CLASSIC AND PALLET BURNERClassic Stainless Steel Chimney SectionsType HT listed, factory-built, all stai

Página 11

18October 2011CHIMNEY COMPONENTS - CLASSIC, E-CLASSIC AND PALLET BURNERChimney Attachment RingABCDEFABCDEFABCDEFABCDEFUsed with electrical conduit (no

Página 12 - Honeywell

October 20111ALPHABETICAL INDEX1-1/4" Thermostatic Valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101-1/4" Thermostatic

Página 13

19October 2011MAINTENANCE, REPLACEMENT AND OPTIONAL PRODUCTS - MAXIMInsulationTransition Box Service Kit (p/n 4337) includes all insulation pieces for

Página 14 - PUSH-FIT FITTINGS

20October 2011Propane Shut-off with Level IndicatorUsed to monitor propane in a BBQ-style tank with Type 1 Acme threads connected to a Maxim furnace.

Página 15 - 1650XL In

21October 2011CHIMNEY COMPONENTS - MAXIMMaxim Stainless Steel Chimney SectionsType HT listed, factory-built, all stainless steel 6" chimney secti

Página 16

22October 2011CHIMNEY COMPONENTS - MAXIMFlashing, Adjustable RoofRequired for chimney installations passing through a roof peak. Available in two mode

Página 17

23October 2011NUMERICAL PARTS LIST100 Soldering Flux (6 oz). . . . . . . . . . . . . . . . . . . . . . . . . . . 9101 Hot Filter, 3/4" FIP. . .

Página 18

24October 2011NUMERICAL PARTS LIST4045 24V Transformer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194082 Chimney Rain Cap . . . . . .

Página 19 - Chimney Support Brace Kit

25October 2011DEFINITIONSASTMAmerican Society for Testing and Materials. Publishes standard specifi cations for terminology, labeling, testing and prod

Página 20

26October 2011Sample Parts List for Forced-Air Heating SystemQTY. P/N DESCRIPTION1 Central Boiler Outdoor Wood Furnace1 107 Heat Exchanger Coil, 125k

Página 21 - AutoRanging DMM

27October 2011QTY. P/N DESCRIPTIONPARTS ORDER LIST

Página 22 - CHIMNEY COMPONENTS - MAXIM

2October 2011WATER-TO-AIR HEAT EXCHANGER PRODUCTSHeat Exchanger Coil (50k Btu)Water-to-air heat exchanger coil with 90˚ 3/4" female pipe thread (

Página 23

3October 2011WATER-TO-AIR HEAT EXCHANGER PRODUCTSLouversBolt on to the face of the heat exchanger to direct heat downward.p/n Description355 Louvers,

Página 24 - NUMERICAL PARTS LIST

4October 2011WATER-TO-AIR HEAT EXCHANGER PRODUCTSWall Mount Fan Convector5-1/2" 18-1/2" 20-3/16" Myson Lo-Line™ RC 6-4 wall mount, fan-

Página 25

5October 2011PUMPS AND PUMP ACCESSORIESTaco Pumps - 006 SeriesTaco 006 Bronze Circulation Pump for domestic water systems. No fl ange required, 3/4&quo

Página 26 - DEFINITIONS

6October 2011PEX PIPE, FITTINGS AND RELATEDPEX Pipe CutterUsed to cut PEX pipe up to 1-1/4" in diameter.p/n Description195 PEX Pipe CutterCentra

Página 27 - SAMPLE PARTS LIST

7October 2011THERMOPEX, CENTRAL THERM, MANIFOLDS AND WATER-TO-WATER EXCHANGERSPEX HangerHalf-moon, nail-in PEX Hanger for securing PEX piping. Availab

Página 28 - PARTS ORDER LIST

8October 2011WATER-TO-WATER EXCHANGERSHeat Exchanger Mounting KitUsed to mount most 5x12 Plate Heat Exchangers (40 or more) with mounting studs to a w

Comentários a estes Manuais

Sem comentários